The TS508D is a four axis in one hybrid servo drive,which means it can separately drive for motors at the same time,and variable current control technology reduce the heating of hybrid servo drive and easy servo motor,and easy servo drive size is small,which save space and freight cost.Below is the details:
Specifications
●Advanced 64bit DSP dual core technology
●Two hybrid servo motors can be synchronous or separately controlled via RS485
●Auto identification the parameters of hybrid servo motor after power up.
●Work smoothly, high torque output at medium/high speed; fast response ,and low heating ,low vibration.
● Opto - isolated differential control signal input,alarm signal OC output
●Adopt advanced variable current and variable frequency technology, it can reduce motor and drive heating and vibration.
●The max pulse frequency is 500KHZ,(the default is 200KHZ)
●The two motors can be controlled by one pulse command or two separately channels pulse command.
●The voltage of input pulse is 4.5vdc—28vdc, no need connect any resistor
●Micro-step setting range is 200~51200,and micro-step can set by serial port
●Over-voltage,under-voltage and over-current protection
Drive feature and selection guide
Drive model TS508D
Voltage 24~50VDC
Max current output 8A
Vector over-load current 12A
weight 0.5kg
Matched closed loop stepper motor TC42(TC42-03, TC42-04,TC42-06,TC42-08)
TC57 series[TC57-10,TC57-22C,TC57-28,TC57-30BK]
TC60 series [TC60-20,TC60-30,TC60-40]
Default (TC28,TC35 or other manufacturer closed loop stepper motor)
Control technology 64bit floating-point dual-core DSP vector closed loop control
Pulse Frequency Max 500KHZ,the default is 200KHZ
Protection Over- voltage, under-voltage ,over-current, over-error alarm
Signal input Pulse,direction,enable signal input, port electric level 4.5VDC—28VDC, no need to connect any resistor
Signal output OC output, the max output current is 100MA, need to connect a pull-up resistor, Max pull-up voltage24VDC
Encoder feedback AB encoder differential input, single-end can customized
Subdivision Default 1600/rcv, DIP to set 200~51200
Open-close selection MT1 to MT4 can set close loop or open loop, set by host computer
Using environment -5℃~55℃
Common Customized Request Based on customer requirements
DIP Function
The drive set micro-step, motor initial direction and other function setting by 8 DIP switches, details as following:
Pulse/REV Table Pul/REV SW1 SW2 SW3 SW4
Default(200) ON ON ON ON
400 OFF ON ON ON
800 ON OFF ON ON
1600 OFF OFF ON ON
3200 ON ON OFF ON
3600 OFF ON OFF ON
6400 ON OFF OFF ON
12800 OFF OFF OFF ON
25600 ON ON ON OFF
1000 OFF ON ON OFF
2000 ON OFF ON OFF
4000 OFF OFF ON OFF
5000 ON ON OFF OFF
7200 OFF ON OFF OFF
8000 ON OFF OFF OFF
10000 OFF OFF OFF OFF
Remark:Above micro-step is the standard of this drive,for others,based on customer’s request or host to set,the range is 200~51200
MOTOR DIR setting
SW5=OFF,4 Motors direction is CCW; SW5=ON,4 motors direction is CW
MODE SELECTION
SW6=OFF, 4 motors are FOC vector control mode;
SW6=ON,4 motors are PM high speed point motion control mode
MOTOR SELECTION
SW7=OFF, choose our TC42 and TC57 hybrid servo motor
SW7=ON ,choose our TC60 and TC86 hybrid servo motor
If for TC28 or other company’s hybrid servo motor, pls contact us for support before purchase
PULSE SELECTION
SW8=OFF,PUL+DIR
SW8=ON, dual pulse mode(CW/CCW)
Current Setting Peak Current RMS Current SW5 SW6 SW7
Default 1.4A(PK) OFF OFF OFF
2.1A 1.5A ON OFF OFF
2.7A 1.9A OFF ON OFF
3.2A 2.3A ON ON OFF
3.8A 2.7A OFF OFF ON
4.3A 3.1A ON OFF ON
4.9A 3.5A OFF ON ON
5.6A 4.0A ON ON ON
TS508D wiring and dimension
closed loop stepper controller
website:http://www.hybridservos.com/hybrid-servo-drive-1
Specifications
●Advanced 64bit DSP dual core technology
●Two hybrid servo motors can be synchronous or separately controlled via RS485
●Auto identification the parameters of hybrid servo motor after power up.
●Work smoothly, high torque output at medium/high speed; fast response ,and low heating ,low vibration.
● Opto - isolated differential control signal input,alarm signal OC output
●Adopt advanced variable current and variable frequency technology, it can reduce motor and drive heating and vibration.
●The max pulse frequency is 500KHZ,(the default is 200KHZ)
●The two motors can be controlled by one pulse command or two separately channels pulse command.
●The voltage of input pulse is 4.5vdc—28vdc, no need connect any resistor
●Micro-step setting range is 200~51200,and micro-step can set by serial port
●Over-voltage,under-voltage and over-current protection
Drive feature and selection guide
Drive model TS508D
Voltage 24~50VDC
Max current output 8A
Vector over-load current 12A
weight 0.5kg
Matched closed loop stepper motor TC42(TC42-03, TC42-04,TC42-06,TC42-08)
TC57 series[TC57-10,TC57-22C,TC57-28,TC57-30BK]
TC60 series [TC60-20,TC60-30,TC60-40]
Default (TC28,TC35 or other manufacturer closed loop stepper motor)
Control technology 64bit floating-point dual-core DSP vector closed loop control
Pulse Frequency Max 500KHZ,the default is 200KHZ
Protection Over- voltage, under-voltage ,over-current, over-error alarm
Signal input Pulse,direction,enable signal input, port electric level 4.5VDC—28VDC, no need to connect any resistor
Signal output OC output, the max output current is 100MA, need to connect a pull-up resistor, Max pull-up voltage24VDC
Encoder feedback AB encoder differential input, single-end can customized
Subdivision Default 1600/rcv, DIP to set 200~51200
Open-close selection MT1 to MT4 can set close loop or open loop, set by host computer
Using environment -5℃~55℃
Common Customized Request Based on customer requirements
DIP Function
The drive set micro-step, motor initial direction and other function setting by 8 DIP switches, details as following:
Pulse/REV Table Pul/REV SW1 SW2 SW3 SW4
Default(200) ON ON ON ON
400 OFF ON ON ON
800 ON OFF ON ON
1600 OFF OFF ON ON
3200 ON ON OFF ON
3600 OFF ON OFF ON
6400 ON OFF OFF ON
12800 OFF OFF OFF ON
25600 ON ON ON OFF
1000 OFF ON ON OFF
2000 ON OFF ON OFF
4000 OFF OFF ON OFF
5000 ON ON OFF OFF
7200 OFF ON OFF OFF
8000 ON OFF OFF OFF
10000 OFF OFF OFF OFF
Remark:Above micro-step is the standard of this drive,for others,based on customer’s request or host to set,the range is 200~51200
MOTOR DIR setting
SW5=OFF,4 Motors direction is CCW; SW5=ON,4 motors direction is CW
MODE SELECTION
SW6=OFF, 4 motors are FOC vector control mode;
SW6=ON,4 motors are PM high speed point motion control mode
MOTOR SELECTION
SW7=OFF, choose our TC42 and TC57 hybrid servo motor
SW7=ON ,choose our TC60 and TC86 hybrid servo motor
If for TC28 or other company’s hybrid servo motor, pls contact us for support before purchase
PULSE SELECTION
SW8=OFF,PUL+DIR
SW8=ON, dual pulse mode(CW/CCW)
Current Setting Peak Current RMS Current SW5 SW6 SW7
Default 1.4A(PK) OFF OFF OFF
2.1A 1.5A ON OFF OFF
2.7A 1.9A OFF ON OFF
3.2A 2.3A ON ON OFF
3.8A 2.7A OFF OFF ON
4.3A 3.1A ON OFF ON
4.9A 3.5A OFF ON ON
5.6A 4.0A ON ON ON